Parametreler.
Üretici kılavuzundaki parametreleri kod veya açıklamayla ara.
PAR LOAD — Load parameter set
8.4 Code table
PAR SAVE — Save parameter set
8.4 Code table
OP DISPLAY — Status display
8.4 Code table
SIGNAL CFG — Signal configuration (predefined basic configurations)
8.4 Code table
OP MODE — Motor control operation Depending on C0086
8.4 Code table
LECOM ADDRESS — LECOM device address
8.4 Code table
NMAX — Max speed Nmax
8.4 Code table
TIR (ACC) — NSET: Acceleration time T ir for the main setpoint of NSET (related to the speed variation 0 ... n max )
8.4 Code table
TIF (DEC) — NSET: Deceleration time T if for the main setpoint of NSET (related to the speed variation n max ... 0)
8.4 Code table
FCODE (QMIN) — FCODE (Q min )
8.4 Code table
FCHOP — Chopper frequency f chop
8.4 Code table
THRESH NACT=0 — Threshold n act =0
8.4 Code table
SLIPCOMP — Slip compensation Only active with sensorless control below
8.4 Code table
IMAX CURRENT — I max limit current Depending on C0086
8.4 Code table
FEEDBACK TYPE — Feedback
8.4 Code table
FCODE (OFFSET) — FCODE (AIN offset)
8.4 Code table
FCODE (GAIN) FCODE (GAIN) — FCODE (AIN gain)
8.4 Code table
DFOUT CONST — DFOUT constant
8.4 Code table
FCODE GEARBOX — FCODE (gearbox factor numerator)
8.4 Code table
GEARBOX DENOM — Gearbox factor denominator
8.4 Code table
MST CURRENT — AIN input signal
8.4 Code table
SET−VALUE RPM — Setpoint selection (rpm)
8.4 Code table
JOG SET−VALUE JOG SET−VALUE — NSET JOG setpoints
8.4 Code table
CTRL ENABLE — RFR controller enable
8.4 Code table
QSP — Quick stop
8.4 Code table
TRIP RESET — Reset fault
8.4 Code table
ACT JOG — NSET: JOG selection
8.4 Code table
NSET−N — NSET: Main setpoint
8.4 Code table
NSET−NADD — NSET: Additional setpoint
8.4 Code table
MCTRL−NSET2 — MCTRL: n set at speed controller input
8.4 Code table
MCTRL−NACT — Actual speed
8.4 Code table
MCTRL−UMOT — Motor voltage
8.4 Code table
UG−VOLTAGE — DC−bus voltage
8.4 Code table
IMOT — Current motor current I mot
8.4 Code table
MCTRL−MSET2 — MCTRL−MSET2 (Mset)
8.4 Code table
MAX TORQUE — Maximum torque
8.4 Code table
ROTOR DIFF — Rotor displacement angle of motor (offset
8.4 Code table
MOT POLE NO. — Number of motor pole pairs
8.4 Code table
ROTOR POS — Motor rotor position 1 revolution = 2048 inc
8.4 Code table
HEATSINK TEMP — Heatsink temperature
8.4 Code table
MOT TEMP — Motor temperature
8.4 Code table
UTILIZATION — Device utilisation I × t of the last 180 s C0064 >100 % releases trip OC5
8.4 Code table
MOTOR LOAD — × t utilisation of the motor
8.4 Code table
ACT TRIP — Trip error message
8.4 Code table
VP SPEED CTRL — V pn speed controller Depending on C0086
8.4 Code table
TN SPEED CTRL — T nn speed controller
8.4 Code table
TD SPEED CTRL — T dn speed controller
8.4 Code table
VP CURR CTRL — V pi current controller Depending on C0086
8.4 Code table
TN CURR CTRL — T ni current controller
8.4 Code table
VP FIELD CTRL — V pF field controller
8.4 Code table
TN FIELD CTRL — T nF field controller
8.4 Code table
MOT POWER — Rated motor power acc. to nameplate Depending on C0086
8.4 Code table
MOT RS — Motor stator resistance Depending on C0086
8.4 Code table
MOT LS — Motor leakage inductance Depending on C0086
8.4 Code table
MOT TYPE — Motor type selection Depending on the controller used
8.4 Code table
MOT SPEED — Rated motor speed Depending on C0086
8.4 Code table
MOT CURRENT — Rated motor current Depending on C0086
8.4 Code table
MOT FREQUENCY — Rated motor frequency
8.4 Code table
MOT VOLTAGE — Rated motor voltage Depending on C0086
8.4 Code table
MOT COS PHI — Motor cos Depending on C0086
8.4 Code table
DRIVE IDENT — Controller identification
8.4 Code table
PASSWORD — Password Parameter access protection for the
8.4 Code table
ROTOR POS ADJ — Rotor position adjustment of a synchronous
8.4 Code table
AIF PROTECT. CAN PROTECT. — Extended password protection for bus
8.4 Code table
S/W VERSION — Software version
8.4 Code table
NSET−TIR (ACCELERATIO — NSET: Additional acceleration for the main setpoint
8.4 Code table
NSET−TIF NSET−TIF — NSET: Additional deceleration times for the main
8.4 Code table
QSP TIF — QSP deceleration time
8.4 Code table
FCODE (GAIN AOUT) — FCODE (AOUT gain)
8.4 Code table
FCODE (OFFSET AOUT) — FCODE (offset AOUT)
8.4 Code table
DIGIN1 POL DIGIN2 POL — DIGINterminal polarity
8.4 Code table
FDO−00 ... — Signal configuration of the free digital
8.4 Code table
DIGOUT1 DIGOUT2 — Signal configuration DIGOUT Depending on C0005
8.4 Code table
DIGOUT1 POL DIGOUT2 POL — Terminal polarity DIGOUT
8.4 Code table
OC6 LIMIT — Threshold for the × t monitoring (motor). 0 = I2 × t monitoring switched off
8.4 Code table
OH7 LIMIT — Temperature for OH7
8.4 Code table
OH4 LIMIT — Temperature for OH4
8.4 Code table
BAUD RATE — LECOM baud rate
8.4 Code table
MONIT CE0 — CE0monitoring
8.4 Code table
OC8 LIMIT — Threshold for the × t advance warning (motor).
8.4 Code table
TAU MOTOR — Thermal time constant of the motor
8.4 Code table
ACT TI — NSET: Active T i times of NSET
8.4 Code table
RFG CHARAC — NSET: Ramp function generator characteristic for main setpoint
8.4 Code table
CONTROL WORD — Control word
8.4 Code table
CTRLWORD C135 — Control word C135
8.4 Code table
FCODE (SETVAL) — Main setpoint
8.4 Code table
START OPTIONS — Start option Automatic start inhibited after
8.4 Code table
STATUS WORD — Status word when linked to automation
8.4 Code table
FDO (DW) — Hexadecimal display of the free digital
8.4 Code table
STATUS WORD 2 — Status word 2
8.4 Code table
STAT.B0 STAT.B2 — Configuration of the free bits of the status
8.4 Code table
(C0156/1) ... — Display of the freely definable bits of the status word
8.4 Code table
ACT TRIP — Trip error message
8.4 Code table
RESET FAILMEM — Reseterror message
8.4 Code table
FAIL NO. ACT FAIL NO. OLD1 — List of faults occurred
8.4 Code table
FAILTIME ACT FAILTIME OLD1 — List of the times when the faults occurred
8.4 Code table
COUNTER ACT COUNTER — List of how often the faults have occurred
8.4 Code table
OV REDUCE — OV reduce
8.4 Code table
UG LIMIT — DC−bus voltage thresholds
8.4 Code table
OP TIMER — Elapsed−time meter Time when the controller was enabled
8.4 Code table
Sonuç bulunamadı.
Başka bir kod veya açıklama deneyebilirsin.
Açıklamalar kılavuzdaki özgün dildedir. Parametreyi değiştirmeden önce ilgili PDF sayfasındaki kapsam, birim, aralık ve erişim koşullarını kontrol et.
← 9300 rehberleri